Boards may be used in roof covering assemblies when specifically recognized in the current icc es report for the roof covering system.
Esr report for roof foam.
And ci max foam sheathing 1 0 evaluation scope 1 1 compliance with the following codes.
2012 and 2009 international building code ibc 2012 and 2009 international residential code irc.
Esr 3702 and this report.
Foam plastic insulation is a two component medium density closedcell spray applied foam plastic with a.
The roof covering systems when installed in accordance with this report have the roof.
6 crushed limestone and is applied at a rate of one batch per 100 square feet 9 3 m2 to a 40 mil 1 mm thickness.
The foam lok fl2000 spray foam insulation may be installed without the 15 minute thermal barrier prescribed in ibc section 2603 4 and irc section r316 4 subject to the following conditions.
Insulation boards are eps foam plastic boards used as nonstructural thermal insulation in wall cavities or ceiling.
Published installation instructions and this report.
Walls the underside of roof sheathing or roof rafters and in exposed as an interior finish.
This report is subject to renewal may 2020.
Icc es evaluation report esr 3398 reissued november 2018.
Reissued may 2019.
Or they may be legacy reports whose term has been extended without a change to the re examination date.
Esr 1061 most widely accepted and trusted page 3 of 6 5 0 conditions of use the foamular foam plastic insulation boards described in this report comply with or are suitable alternatives to what is specified in those codes listed in section 1 0 of this report subject to the following conditions.
All of the evaluation reports that may be downloaded from this web site are valid although some have re examination dates that have passed.
Of the coated foam roof system with 64 pounds 29 kg of white no.
The spray applied foam roofing insulationmust be s.
Coated foam plastic roof covering systems must comply with the applicable code laolla industries p inc.
In the case of the latter the reports are currently undergoing re examination as required by icc es rules of procedure.
Evaluation reports icc es esr 1284 gacoflex urethane rubber walking deck and roof covering evaluation reports mimi dade noa 18 0424 gacoflex u64 u66 u91 pedestrian and vehicular traffic deck waterproofing systems.
The evaluation report for the roof covering material must recognize the expanded polystyrene foam plastic insulation as part of a class a b or c roof assembly tested in accordance with astm e108 or ul 790.
If there are any conflicts between the report holder s installation instructions and this report this report governs.
Dc315 esr 3702 is applied to all exposed foam surfaces at a minimum application rate of 22 wet mils.